Door Model Names in Quotations: How to Avoid Confusion Between Look-Alike Designs

Similar-looking doors with different names cause pricing errors and wrong deliveries. This guide proposes a simple coding system that keeps every design variation clear between buyer and factory.

A clear set of door model codes in your quotation is the simplest way to stop two similar-looking doors from being priced, produced or shipped as the same item. When a buyer writes "Flush door, oak" and the factory reads it as a different flush design, the error usually appears only at sample approval, or worse, at installation. This guide proposes a practical coding system that you and your factory can share from the first enquiry to the final packing list.

Why look-alike doors cause so many quotation errors

Hotel projects rarely use one door. A single building can include guest room doors, bathroom doors, wardrobe doors, connecting doors and service doors, and many of them look nearly identical in a render. The differences are in the details: a groove position, a leaf thickness, a veneer direction or a hardware preparation.

When these details are not in the name, they live in emails, sketches and memory. That is where mistakes start.

Typical problems include:

  • Two doors share one name but have different thicknesses or cores.
  • One door has several names across the buyer's drawings, the designer's schedule and the factory's price list.
  • A handing or hardware change is agreed by email but never reaches the production sheet.
  • A revised finish keeps the old model name, so the first and second versions are confused.

Model names, reference numbers and type codes: know the difference

Much of the confusion comes from mixing three different ideas. Separating them makes the whole system easier to manage.

  • Model name: the commercial or design name of a style, such as "Grooved" or "Shaker". It describes the look but not the specification.
  • Door type code: a short code that fixes the technical build: leaf size family, thickness, core, finish family and fire or acoustic requirement.
  • Door reference number: the location tag from the door schedule, such as the door at room 0412 or the wardrobe in room type A. It tells the installer where the door goes.

A model name can be shared by many type codes, and a type code can appear in hundreds of locations. If you keep these layers separate, your quotation stays readable and your factory can price each layer accurately.

A simple coding structure you can adopt

You do not need a complicated system. A code of five or six short segments is usually enough, and it should be readable by a person, not only by software. The example below is a suggestion; adapt the segments to your own project.

Suggested format

Use this pattern: Function – Model – Leaf – Finish – Option – Revision.

SegmentMeaningExample
FunctionWhere the door is usedGR (guest room), BT (bathroom), WD (wardrobe), SV (service)
ModelDesign familyFL (flush), GV (grooved), PN (panelled), GL (glazed)
LeafLeaf type and thicknessS45 (single leaf, 45 mm (1.8 in)), D45 (double leaf)
FinishFinish familyVN (veneer), LQ (lacquer), HP (HPL)
OptionTechnical add-onF (fire-rated), A (acoustic), E (electronic lock prep)
RevisionVersion letterA, B, C

A guest room door could then read GR-GV-S45-VN-FE-B: a grooved, single-leaf, 45 mm veneered door with fire rating and electronic lock preparation, second revision. Anyone reading the code knows what it is before opening a drawing.

Keep codes short and stable

Avoid codes that depend on a colour name or a supplier's catalogue number, because both can change. Use letters that the whole team can remember and write a one-page key that is attached to every quotation request. Do not reuse a retired code for a different door.

Where the location reference fits

The type code describes what the door is. The door reference number, taken from your door schedule, describes where it goes. Keep them in separate columns.

For example, your schedule might list door 0412-A in the room entrance column with type code GR-GV-S45-VN-FE-B and a handing note. The factory can then group all identical type codes for pricing and production, while the installer still sees a location for each leaf. This is also the clearest way to apply door schedule naming consistently across floors and buildings.

What to include in the quotation line

A quotation line that carries only a code is not enough. The code should be backed by a short specification that does not change between versions. At a minimum, each line should show:

  1. The type code and the model name in words.
  2. Leaf dimensions in metric first, with imperial in brackets where useful.
  3. Core type, thickness and finish description.
  4. Hardware preparation, such as hinge count, lock routing or closer preparation.
  5. Quantity, with handing split if relevant.
  6. Whether frames, architraves and hardware are included or excluded.

When two lines look alike, add a short "difference note", for example "same as GR-GV-S45-VN-FE-B but 40 mm (1.6 in) leaf and no fire rating". This one sentence prevents many disputes.

Handling revisions without losing control

Design changes are normal in hotel projects, so build a revision step into the system from the start. Each time a specification changes, update the revision letter and note what changed.

A practical revision routine looks like this:

  • Change the letter whenever dimensions, core, finish, hardware preparation or rating changes.
  • Keep the old revision in the file, marked as superseded.
  • Send the updated schedule and quotation together, never separately.
  • Ask the factory to confirm the revision letter in writing before production starts.

This matters most when a sample has been approved. If the approved sample is revision B, the production order should state revision B, not just the model name.

Matching codes across drawings, samples and packing

A code is only useful if it follows the door through the whole process. Check that the same code appears on:

  • The door schedule and elevation drawings.
  • The quotation and the order confirmation.
  • The sample or mock-up door label.
  • Production sheets and quality checks.
  • Packing labels and the packing list, together with the location reference.

When the code printed on a crate matches the code in your schedule, receiving checks become faster, and site teams can place each leaf without guessing.

Common mistakes to avoid

  • Using only marketing names: two designers can describe "minimal flush" very differently.
  • Overloading one code: if one code covers three different thicknesses, it is not a code.
  • Mixing hardware into the model name: keep hardware as an option segment so you can change it without renaming the design.
  • Different codes in different documents: choose one master schedule and treat all other documents as copies.
  • No key or legend: the factory cannot guess what your letters mean.

A short checklist before you send the request

  1. Does every distinct build have its own type code?
  2. Is each location linked to a code in the door schedule?
  3. Does the quotation line repeat the key specification, not only the code?
  4. Are revision letters visible and confirmed?
  5. Is the code key attached to the request?

Conclusion

Good coding is not about adding paperwork. It gives you and your factory one shared language, so that price, sample, production and delivery all refer to the same door. Even a simple six-segment code removes most of the guesswork that causes look-alike mix-ups.

If you are preparing a hotel door package, send us your door schedule or drawings, and tell us how you currently name your doors. We can review them, suggest a coding structure that fits your project and come back with a clear quotation that follows your references.

Sıkça Sorulan Sorular

What is the difference between a door model code and a door reference number?

A door model or type code describes what the door is: its design, thickness, finish and technical options. A door reference number describes where it is installed, such as a room or opening number. Keeping them separate lets the factory group identical doors for pricing while installers still see each location.

How long should a door type code be?

Keep it short enough to read at a glance, usually five or six segments of one to three characters each. It should cover function, model, leaf, finish, technical options and revision. If a code needs a long explanation, split the build into separate codes instead.

Should I use the factory's catalogue names or my own codes?

Use both. Keep the factory's model name for the design look, and add your own project code for the full specification. That way the quotation stays easy to match with a catalogue, while your schedule remains consistent across designers, contractors and suppliers.

How do I handle design changes after quotation?

Update the revision letter whenever dimensions, core, finish, hardware preparation or ratings change. Send the revised schedule and quotation together, and ask the factory to confirm the new revision in writing before production starts. Keep earlier versions on file, marked as superseded.

Can the same code system work for wardrobe and bathroom doors?

Yes. Add a function segment at the start, such as GR for guest room, BT for bathroom or WD for wardrobe, then use the same model, leaf, finish and option segments. One structure across all door types keeps the full project schedule consistent.

Every hotel project is different. Send us your drawings or room schedule for a tailored proposal on materials, lead time and shipping.

Related products

All Door Models

Get a quote for Door Models

Share dimensions and quantities; we will prepare a quote for your project.