A good hotel guest room door specification answers every question a factory would otherwise have to ask you, so the first quotation you receive is already close to the final one. The easiest way to write one is to follow the order of a spec sheet: opening, leaf, core, finish, frame, hardware preparation and documents. This guide goes through each line item and explains what to write, and why it matters.
Why a line-by-line spec sheet works
Most quotation delays come from missing information, not from complicated doors. A single sheet with fixed fields lets you compare offers from different factories on equal terms. It also becomes the reference document for sampling, production and delivery inspection.
If you already have a door schedule, use it as the base and add one spec sheet per door type. Guest room entrance doors, bathroom doors and connecting doors usually need separate sheets.
Line 1: Door type, quantity and location
Start with the basics so the factory can group items correctly:
- Door mark or type code: for example GR-01 for the guest room entrance.
- Quantity per type: including a realistic allowance for spares and mock-up rooms.
- Location: room entrance, bathroom, wardrobe, connecting opening or suite entrance.
- Handing: left or right hand, and inward or outward swing, as marked on the plans.
Handing is a frequent source of errors in large orders. Mark it from one consistent viewpoint and state that viewpoint on the sheet.
Line 2: Opening and leaf size
Give the structural opening or the clear opening that the design requires, then the leaf dimensions that follow from it. Write sizes in millimetres first, with inches in brackets where your team needs them, for example 900 x 2100 mm (35.4 x 82.7 in).
Do not assume a standard width. Local codes, accessibility rules and brand standards vary between regions, and a bathroom door often differs from the entrance. Also state the floor finish and the intended undercut, because carpet, stone and timber floors need different gaps.
Line 3: Door leaf thickness
Door leaf thickness affects weight, sound performance, hinge selection and the feel of the door when it closes. Many hotel entrance doors are specified thicker than internal residential doors, but the right figure depends on the brand standard, the fire and acoustic requirements and the hardware you choose.
Write the finished thickness, including veneer or laminate, and state the tolerance you accept. If a fire rating or acoustic target applies, confirm that the thickness matches the tested construction, since ratings belong to a complete assembly rather than to a leaf alone.
Line 4: Core construction
The core is the largest single factor in durability, weight and cost. A solid core door for a hotel is usually chosen for guest room entrances where sound, security feel and impact resistance matter. Lighter cores can suit less demanding openings.
| Core type | Typical use | Points to check |
|---|---|---|
| Solid timber or stave core | Premium entrances, statement doors | Weight, movement with humidity |
| Solid particleboard or chipboard core | Guest room entrances, fire-rated assemblies | Density, screw holding, edge sealing |
| Mineral or fire-resistant core | Fire-rated doors | Test report for the full assembly |
| Honeycomb core | Internal, low-load openings | Hardware blocking, sound performance |
State the core type, any fire or acoustic performance required and whether reinforcement blocks are needed behind locks, closers and hinges. A door that looks right but has no solid backing for fixings will loosen early in service.
Line 5: Face material and finish
Define the surface in three parts: the facing material, the species or pattern, and the coating. Options usually include veneer with lacquer, HPL, laminate, painted MDF or oil finishes. Each reacts differently to trolleys, cleaning chemicals and sunlight.
- Facing: veneer species and cut, HPL code, or paint-grade substrate.
- Finish reference: a physical sample, or a RAL or Pantone code for painted doors.
- Sheen level: matt, satin or gloss, noted separately from colour.
- Edge treatment: solid edge, ABS or veneer edge, and whether edges are sealed.
Colour on a screen or a small sample can look different under room lighting, so reference an approved sample and keep it on file. Edges are where wear starts first in hotels, so name the edge material explicitly rather than leaving it to the factory's default.
Line 6: Door frame and architrave
List the frame material, section, rebate and the wall thickness it must fit. Timber, steel and concealed frames all appear in hotel projects, and each changes how the leaf is detailed and installed.
Include the architrave or casing profile, the finish of the frame (matching or contrasting with the leaf) and any seal grooves for smoke, acoustic or draught gaskets. If the frame is supplied by another trade, record who is responsible for coordination.
Line 7: Hardware preparation
Door hardware preparation is where a spec sheet often falls short. The factory can only machine the leaf correctly if it knows the exact hardware models, or at least their templates. Specify:
- Hinges: number, type, size and load rating, with positions measured from the top of the leaf.
- Lock and latch: mortise lock case dimensions, backset, and the electronic lock supplier and model.
- Routing and cable paths: for card readers, door contacts or wired locks.
- Closer and stop: closer type, fixing plates and any floor or wall stops.
- Peephole and signage: position, diameter and any room number plate details.
- Handle and pull heights: measured from the finished floor level.
Ask the lock supplier for current templates and confirm them before production. Changing a lock model after the leaves are machined usually means rework, so freeze the hardware choice before sampling.
Line 8: Seals, protection and accessories
Add the details that affect daily performance: perimeter seals, drop-down bottom seals, kick plates and any protective strips. For doors facing noisy corridors, specify the acoustic target and the seal arrangement that supports it, instead of listing the seal alone.
Line 9: Performance requirements and documents
Write down any fire rating, acoustic value, emission class or accessibility requirement that applies, and the destination country's rules behind it. Then list the documents you need: technical drawings, test reports, finish samples and a product data sheet. Do not request a certificate that the product does not actually hold; ask the factory what it can supply and compare that with your tender requirements.
Line 10: Sampling, packing and delivery
Finish the sheet with the commercial and logistical items:
- Mock-up or prototype door and who approves it.
- Labelling by room number or door mark.
- Packing method for leaves, frames and finished edges.
- Incoterms such as EXW, FOB, CIF or DAP, and the delivery sequence by floor or block.
Lead time depends on quantity, finish approval, hardware readiness and the shipping route, so ask for a schedule linked to your construction programme rather than a single figure.
A quick checklist before you send the sheet
- Every door type has a mark, quantity, handing and size.
- Leaf thickness and core are stated, with tolerances.
- Finish is tied to a physical sample or colour code.
- Frame section matches the wall thickness.
- Hardware models and templates are confirmed.
- Performance requirements and documents are listed.
- Packing, labelling and shipping terms are defined.
Next step
If you are preparing a hotel project, send us your door schedule or drawings. We will review the specification with you, point out any gaps in thickness, core or hardware preparation, and come back with a quotation and options for your delivery route.
Sıkça Sorulan Sorular
What should a hotel guest room door specification include?
It should cover door type and quantity, handing, opening and leaf size, leaf thickness, core construction, face material and finish, frame details, hardware preparation, seals, performance requirements, documents, packing and delivery terms. One sheet per door type keeps quotations accurate and easy to compare.
Does a hotel guest room door need a solid core?
Entrance doors usually benefit from a solid core because it improves sound reduction, impact resistance and screw holding. Fire or acoustic requirements may also dictate the construction. Lighter cores can work for low-load internal openings, so decide by door location and applicable regulations.
How do I choose the right door leaf thickness?
Base it on brand standards, fire and acoustic needs, hardware compatibility and the weight you want the hinges to carry. Ratings apply to tested assemblies, so confirm that the thickness matches the tested construction. Always state finished thickness and tolerance on the spec sheet.
What is door hardware preparation?
It is the machining of the leaf and frame for hinges, locks, closers, viewers and cable paths before finishing. The factory needs exact hardware models or templates to do this correctly. Confirm electronic lock details with the supplier before production starts.
What do I need to send a factory for an accurate door quotation?
Send a door schedule, drawings with handing and sizes, your preferred core and finish, frame details, hardware models, performance requirements and delivery terms. A reference sample or colour code for the finish also helps avoid assumptions.
Every hotel project is different. Send us your drawings or room schedule for a tailored proposal on materials, lead time and shipping.