Shutter Cabinet Reference Guide for Architects: Quick Specification Values for Early Design Stage
A practical set of rule-of-thumb dimensions, options and checks for shutter cabinet specification at concept stage. Use them to size niches and write early notes, then confirm details with the factory.
For shutter cabinet specification, architects need working values at concept stage: roughly how deep, wide and tall a slatted or tambour unit can be, and what space it needs around it. The figures below are planning ranges, not fixed limits. They help you reserve the right space in plans and sections before a factory reviews your drawings.
Every value here depends on the mechanism, the slat material and the project, so treat the numbers as starting points. Confirm them against shop drawings and a mock-up room before they become contract dimensions.
What a shutter cabinet is, in specification terms
A shutter cabinet uses a door that rolls, slides or folds rather than swinging on hinges. The main families are tambour (roller) doors with linked slats, and louvred doors with fixed or adjustable slats. Each family changes the clearances you must allow, so name the type in your early notes.
- Tambour roller door: flexible slats run in side tracks and retract into a housing or around a curve.
- Louvred hinged or sliding door: slats are fixed in a frame or adjustable, and the door moves like a conventional one.
- Retraction style: vertical roll-up, horizontal slide or side-fold each need different space above, beside or behind the opening.
Rule-of-thumb depths for concept drawings
Depth is the dimension architects most often under-allocate. A tambour unit needs the usable internal depth plus room for the track and the retracted door.
| Use | Typical planning depth | Notes |
|---|---|---|
| Wardrobe, hanging rail | 55-60 cm (21.7-23.6 in) | Hangers need space across the width; check door retraction does not collide with garments. |
| Shelved storage, linen, amenities | 35-45 cm (13.8-17.7 in) | Shallower units save floor area in small rooms. |
| Minibar or coffee station | Depends on the appliance | Add ventilation and steam clearance; see the appliance data sheet. |
| TV or media unit | Depends on the equipment | Allow for cable routing, heat and remote signal. |
These are planning values for early design. Actual interior depth is smaller than the overall depth once panel thickness, back panel and track are deducted.
Widths and heights: where the limits come from
Width and height limits are set by slat stiffness, the mechanism and how the door will be used. Very tall doors can bow or become heavy to operate, and very wide openings place more load on the guide system.
- Height: tall wardrobe doors are possible, but long slats are more prone to bowing. Ask the factory for height limits for your chosen slat material before fixing floor-to-ceiling designs.
- Width: wide runs are usually split into several units or modules. This also makes transport, installation and later repair easier.
- Modules: using one or two standard module widths across the hotel simplifies drawings, ordering and spare parts.
If you are working towards a long wardrobe wall, think in modules with aligned slat lines rather than a single continuous door.
Clearances to reserve around the unit
Shutter doors need space that hinged doors do not, and it is easy to miss in early plans. Mark these areas in your sections.
- Retraction housing or roll space: above or beside the opening, depending on direction. The housing height or width reduces usable storage.
- Track and side gap: a small gap each side for the guide, plus allowance for wall irregularities.
- Wall gap and skirting: allow for tolerances so the unit can be levelled and the doors aligned.
- Ventilation: units that conceal electronics or appliances need airflow openings; louvred panels can help.
- Service access: maintenance teams should be able to reach the track and mechanism without removing the whole unit.
Choosing the door type at concept stage
A simple decision path avoids reworking later. Start with what the unit stores, then the room layout, then the look.
- Tight circulation or door-swing conflicts: a tambour or sliding shutter avoids the swing arc.
- Humid or warm climates, or storage needing airflow: louvred doors let air move, with a trade-off in dust.
- Concealed appliances: tambour doors that retract fully give access without a door in the way; check heat and steam.
- Public or back-of-house areas: wipe-down finishes and robust mechanisms matter more than fine detail.
Materials and finishes to name in early notes
You do not need a full finish schedule at concept stage, but naming the slat material and finish family avoids misunderstandings in the first quote. Common options include solid timber, veneer, MDF with lacquer or paint, laminate and PVC slats.
- State the slat material and the intended finish type.
- Note any colour reference system, such as RAL or NCS, or a timber species and tone.
- Flag wet or high-humidity locations early, since they limit material choices.
- Record fire requirements for the destination country, as fire-retardant (FR) material choices can affect cost and lead time.
Natural timber varies in grain and tone, so ask for physical samples rather than relying on photographs.
Slat size and profile: decisions that affect the look
Slat width, spacing and profile (flat, rounded or grooved) define the character of the door. Narrower slats read as finer and more refined, but they add more joints and more cleaning edges. Wider slats look bolder and simpler.
At concept stage, a sketch showing the slat rhythm in elevation is usually enough. The factory can then advise on practical slat sizes for the mechanism and height you need.
Items to leave open until the factory reviews
Some values should not be fixed by an architect alone. Leave them as notes or ranges until the manufacturer has seen the drawings.
- Exact mechanism type, cycle rating and track material.
- Maximum door height and width for the chosen slat material.
- Cord, spring or counterbalance system and soft-close options.
- Packing method, shipping terms (for example EXW, FOB, CIF or DAP) and delivery sequence.
- Lead time, which depends on quantity, finishes and the approval process.
An early-stage checklist
- Define what each unit stores and who uses it.
- Choose tambour or louvred, and the retraction direction.
- Allocate depth, housing space and side gaps in plans and sections.
- Group units into a few standard modules.
- Name the slat material, finish family and colour reference.
- Note ventilation, heat, humidity and fire requirements.
- Specify units of measure: metric first, with imperial where the project requires it.
- Plan a mock-up room to test operation and appearance.
Preparing for the factory conversation
When you are ready to talk to a manufacturer, send plans, sections and a simple schedule of units by room type. Include the destination country and any local standards. This lets the factory check your planning values, suggest adjustments and respond with a realistic quotation.
Next step
If you are at concept stage on a hotel project, send us your drawings or room schedule. We will review the shutter cabinet requirements, comment on the planning values and advise on materials, lead time and shipping options for your destination.
Sıkça Sorulan Sorular
What depth should I allow for a shutter cabinet at concept stage?
As a rough guide, allow about 55-60 cm (21.7-23.6 in) for hanging wardrobes and 35-45 cm (13.8-17.7 in) for shelved storage. Add space for the track and retracted door. Confirm the exact figure with the factory, because mechanism and material change it.
How tall can a shutter cabinet door be?
It depends on the slat material, slat construction and mechanism. Taller doors are more prone to bowing and can be harder to operate smoothly. Ask the manufacturer for height limits for your chosen material before fixing floor-to-ceiling dimensions in your design.
Do shutter cabinets need extra clearance compared with hinged doors?
Yes, in different places. You avoid a door-swing arc, but you must reserve space for the retraction housing, side tracks and tolerance gaps. Units that hold appliances or electronics also need ventilation openings.
Should I specify tambour or louvred doors in early drawings?
Name the type you expect, since it changes clearances and cost. Tambour doors suit tight layouts and concealed storage, while louvred doors suit storage that needs airflow. You can revise the choice after the factory reviews your drawings.
What information should architects send to a factory for a first review?
Send plans, sections, a unit schedule by room type, preferred slat material and finish, colour references, the destination country and any fire or emission requirements. This helps the factory check your values and quote accurately.
Every hotel project is different. Send us your drawings or room schedule for a tailored proposal on materials, lead time and shipping.