Door Sizes and Standards Around the World: Metric, Imperial and Regional Opening Dimensions

Standard interior door sizes differ between metric, imperial and mixed markets. This guide gives export buyers a practical reference for specifying leaf, frame and opening dimensions correctly for each region.

Standard interior door sizes are not the same everywhere. A leaf that is routine in the UK may not suit a Gulf villa, and an American 36 in door is not simply a metric 900 mm door. If you are buying for several markets, you need to know which dimensions are common, how openings differ from leaves, and what to confirm before production starts.

This guide is a worldwide reference for hotel developers, designers and contractors. The figures below are typical market conventions, not fixed rules. Local codes, existing openings and project drawings always take priority, so treat the tables as a starting point for your door schedule.

Leaf size, frame size and opening size: three different numbers

Most specification errors start with confusion over which dimension is being quoted. Three measurements are involved, and they are not interchangeable.

  • Door leaf size: the width and height of the moving door panel itself.
  • Frame (set) size: the outer size of the frame, including jambs and head.
  • Structural (masonry) opening: the rough hole in the wall, which must be larger than the frame to allow fixing and adjustment.
  • Clear opening: the usable passage width once the door is open, which is always smaller than the leaf width.

Always state on your schedule which dimension you mean. A line reading only "900 x 2100" can be read as a leaf, a frame or an opening, and each reading gives a different door.

Metric markets: common leaf and opening sizes

Across most of Europe, the Middle East, Africa, Central Asia and much of Asia, doors are specified in millimetres. Heights are usually between 2000 and 2200 mm, while widths step in increments that vary by country.

Region or marketTypical leaf heights (mm)Typical leaf widths (mm)Notes
UK (metric leaf sizes)1981, 2040610, 686, 762, 838, 926Derived from imperial sizes; 1981 mm is 6 ft 6 in
Continental Europe2000 to 2110610 to 1010, often in 125 mm stepsVaries by country; DIN-based sizes common in Germany
Turkey and Gulf region2000 to 2200700 to 1000Taller leaves are increasingly used in hotels
Central Asia and CIS2000 to 2100600 to 900Often follows older regional standards
Africa2000 to 2100700 to 900Mixed influence from European and British practice

Treat this as a door size chart for orientation only. Even inside one country, developers and manufacturers use different grids, so confirm the exact modular size with the project architect.

Imperial door sizes: the North American and legacy convention

The United States, Canada and some other markets use feet and inches. Imperial door sizes are normally quoted by nominal leaf width and height, and the standard height is 6 ft 8 in (about 2032 mm), with 7 ft and 8 ft doors also common in higher-end work.

Nominal sizeApprox. metric equivalentTypical use
24 in x 80 in610 x 2032 mmClosets, small service rooms
28 in x 80 in711 x 2032 mmSmall bathrooms
30 in x 80 in762 x 2032 mmBathrooms, bedrooms
32 in x 80 in813 x 2032 mmBedrooms
36 in x 80 in914 x 2032 mmMain entries, accessible routes
36 in x 96 in914 x 2438 mmTall doors for high ceilings

A conversion is not a specification. American nominal sizes usually describe slightly undersized leaves that fit prehung frames, so a "36 in" door is often a few millimetres smaller than 914 mm. Ask for dimensioned drawings in millimetres for every leaf to remove any ambiguity.

Why 900 mm is not always the default

Many buyers assume a 900 mm leaf works everywhere. In practice, the right size depends on the market, the building type and the accessibility rules in force.

  • In UK-influenced markets, 838 mm and 762 mm leaves are far more common than 900 mm.
  • In North America, 914 mm (36 in) is the accessible-route reference, while bedrooms often use 813 mm (32 in).
  • In many European countries, 860, 885 or 985 mm leaves follow national grids.
  • In the Gulf, hotels often prefer wider and taller leaves for a more generous look.

For a multi-country portfolio, build a size matrix per market rather than forcing one metric size across every property.

Typical hotel door sizes by opening type

Hotels use a limited set of opening types, and each has its own habits regardless of country. These ranges are common starting points, not rules.

  • Guest room entrance: usually 900 to 1000 mm leaf width, sometimes wider on accessible rooms.
  • Bathroom door: 700 to 900 mm, depending on layout and whether it is hinged, sliding or pocket.
  • Wardrobe doors: sized to the joinery module rather than to a standard door grid.
  • Suite entrances: often double-leaf, with one active and one fixed or equal leaves.
  • Service and back-of-house: sized for trolleys, so 900 mm or more is common.

Furniture delivery also matters. Check that beds, wardrobes and large case goods can pass through the opening before you finalise leaf widths.

Frame allowances and structural opening rules

Once you know the leaf size, the frame and rough opening follow from a few allowances. These vary by frame type and construction, so confirm the exact figures with your manufacturer and installer.

  1. Add the frame rebate and the clearance gaps on both sides and at the head to the leaf size to get the frame opening.
  2. Add the frame thickness on each side to get the outer frame size.
  3. Add a fixing and adjustment allowance around the frame to get the structural opening.
  4. Check wall thickness, because frame depth must match the finished partition including boards and plaster.

A common rule of thumb is to leave a few millimetres of gap around the leaf and a larger allowance between the frame and the wall. Because the exact values depend on the system, ask for a section drawing with every dimension marked.

Floor finishes and undercuts

The bottom gap depends on the floor, not just the door. Thick carpet, stone with underfloor heating and timber flooring all need different clearances. If the floor finish is not yet decided, record the finished floor level on the schedule so the factory can cut the leaf height correctly. Fire doors and acoustic doors have their own rules on gaps, so check them before you finalise cutting.

Accessibility and regional codes

Accessibility regulations set minimum clear opening widths, and these differ by country. A leaf that looks wide enough may not meet the clear-opening requirement once hinges and the open leaf thickness are counted. Verify the figure that applies to the destination, and add allowance for the hardware you plan to use.

Fire, acoustic and security requirements may also fix certain dimensions, because tested door assemblies are approved at specific sizes and configurations. If a tested size does not match your opening, talk to the manufacturer early.

How to prepare a size reference for export orders

A clear process prevents costly errors on international projects. Follow these steps before you request a quotation.

  1. List every opening by location, with leaf, frame and structural opening sizes in millimetres.
  2. Add imperial values in brackets where the client team works in inches.
  3. Mark door handing and swing direction for each opening.
  4. Record wall thickness and frame type.
  5. Note the finished floor level and any special undercut.
  6. Flag any openings with fire, acoustic or accessibility requirements.

If you provide this information with your drawings, we can check it against the production process and highlight any items that need correction before manufacturing starts.

Custom sizes and tolerances

Because Palmiye produces to project drawings, we are not limited to one regional grid. Custom widths and heights are possible, and taller leaves for high ceilings are common in hospitality work. Custom sizing does affect material choice, hinge numbers and lead time, so it is worth settling dimensions before mock-up approval.

Also agree acceptable tolerances in advance. Wooden leaves can move slightly with humidity, so your drawings should state the tolerance on width, height and squareness that you expect on delivery.

Common mistakes to avoid

  • Mixing leaf sizes and opening sizes on the same schedule.
  • Converting imperial to metric without confirming the actual manufactured size.
  • Assuming one size suits all markets in a multi-country portfolio.
  • Ignoring wall thickness when choosing frames.
  • Fixing leaf height before the floor finish is known.

Next step

If you are specifying doors for a hotel or residential project in any market, send us your door schedule or drawings. We will review sizes, flag conflicts between leaf, frame and opening dimensions, and suggest a practical configuration for your destination.

Sıkça Sorulan Sorular

What are standard interior door sizes in metric countries?

There is no single global standard. Heights usually fall between 2000 and 2200 mm, and widths commonly range from 600 to 1000 mm. Exact grids differ by country, so confirm the local modular size with your architect before ordering.

What is the standard interior door size in the US?

The usual height is 6 ft 8 in (about 2032 mm), with widths such as 28, 30, 32 and 36 inches depending on the room. Taller 7 ft and 8 ft doors are also used, especially in higher-end or high-ceiling projects.

Is a 900 mm door the same as a 36 inch door?

Not exactly. A 36 inch door is about 914 mm nominally, and manufactured leaves are often slightly smaller. For export orders, specify dimensions in millimetres on drawings so the factory builds exactly the size you need.

What is the difference between door leaf size and opening size?

The leaf size is the door panel itself. The opening size is the space in the wall, which must be larger to fit the frame and allow adjustment. Always label which dimension you mean on your schedule to avoid errors.

Can a factory make custom door sizes for export projects?

Yes, a factory working to project drawings can produce non-standard widths and heights. Custom sizes may affect hinge selection, materials and lead time, so agree dimensions and tolerances before you approve the mock-up.

Every hotel project is different. Send us your drawings or room schedule for a tailored proposal on materials, lead time and shipping.

Related products

All Door Models

Get a quote for Door Models

Share dimensions and quantities; we will prepare a quote for your project.